authorLinus Torvalds <torvalds@linux-foundation.org>2026-03-20 09:52:45 -0700
committerLinus Torvalds <torvalds@linux-foundation.org>2026-03-20 09:52:45 -0700
commit007fe2321509a8287050413655f460d4c5ad8e8c (patch)
tree2f971063218dfcb9de7671e317afcedc98ee54f0 /Documentation
parentc715f13bb30f9f4d1bd8888667ef32e43b6fedc1 (diff)
parent4221f30e3e0a2507641b3397d21aff9e71e749f8 (diff)
Merge tag 'regulator-fix-v7.0-rc4' of git://git.kernel.org/pub/scm/linux/kernel/git/broonie/regulator
Pull regulator fix from Mark Brown: "Just one fix here from Hugo Villeneuve, the documentation for some of the regulator DT properties had been cut'n'pasted so that if anyone actually read it they'd be informed that those properties had completely incorrect meanings" * tag 'regulator-fix-v7.0-rc4' of git://git.kernel.org/pub/scm/linux/kernel/git/broonie/regulator: regulator: dt-bindings: fix typos in regulator-uv-* descriptions
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/devicetree/bindings/regulator/regulator.yaml4
1 files changed, 2 insertions, 2 deletions
diff --git a/Documentation/devicetree/bindings/regulator/regulator.yaml b/Documentation/devicetree/bindings/regulator/regulator.yaml
index 042e56396399..019aeb664cae 100644
--- a/Documentation/devicetree/bindings/regulator/regulator.yaml
+++ b/Documentation/devicetree/bindings/regulator/regulator.yaml
@@ -168,7 +168,7 @@ properties:
offset from voltage set to regulator.
regulator-uv-protection-microvolt:
- description: Set over under voltage protection limit. This is a limit where
+ description: Set under voltage protection limit. This is a limit where
hardware performs emergency shutdown. Zero can be passed to disable
protection and value '1' indicates that protection should be enabled but
limit setting can be omitted. Limit is given as microvolt offset from
@@ -182,7 +182,7 @@ properties:
is given as microvolt offset from voltage set to regulator.
regulator-uv-warn-microvolt:
- description: Set over under voltage warning limit. This is a limit where
+ description: Set under voltage warning limit. This is a limit where
hardware is assumed still to be functional but approaching limit where
it gets damaged. Recovery actions should be initiated. Zero can be passed
to disable detection and value '1' indicates that detection should